
<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Expo Technologies</title>
	<atom:link href="http://www.expoworldwide.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.expoworldwide.com</link>
	<description>Purge + Pressurization + Innovation</description>
	<lastBuildDate>Tue, 21 May 2013 16:44:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=343</generator>
		<item>
		<title>Auto Draft</title>
		<link>http://www.expoworldwide.com/purge-pressurization/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/#comments</comments>
		<pubDate>Wed, 30 Nov -0001 00:00:00 +0000</pubDate>
		<dc:creator>admin</dc:creator>
		
		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1632</guid>
		<description><![CDATA[<p></p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Auto Draft</title>
		<link>http://www.expoworldwide.com/purge-pressurization/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/#comments</comments>
		<pubDate>Wed, 30 Nov -0001 00:00:00 +0000</pubDate>
		<dc:creator>Documentcontrol</dc:creator>
		
		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1637</guid>
		<description><![CDATA[<p></p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Auto Draft</title>
		<link>http://www.expoworldwide.com/purge-pressurization/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/#comments</comments>
		<pubDate>Wed, 30 Nov -0001 00:00:00 +0000</pubDate>
		<dc:creator>admin</dc:creator>
		
		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1266</guid>
		<description><![CDATA[<p></p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Auto Draft</title>
		<link>http://www.expoworldwide.com/purge-pressurization/auto-draft/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/auto-draft/#comments</comments>
		<pubDate>Thu, 22 Sep 2011 15:40:22 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Purge and Pressurization]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1130</guid>
		<description><![CDATA[<p></p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/auto-draft/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/auto-draft/">Auto Draft</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/auto-draft/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SmartPurge II</title>
		<link>http://www.expoworldwide.com/purge-pressurization/smartpurge-ii/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/smartpurge-ii/#comments</comments>
		<pubDate>Thu, 24 May 2012 16:33:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Purge and Pressurization]]></category>
		<category><![CDATA[X-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1608</guid>
		<description><![CDATA[<p>The SmartPurge II system from Expo is designed to change the pressurized enclosure internals from a Zone 1 area into a safe area.</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/smartpurge-ii/">SmartPurge II</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>The SmartPurge II system from Expo is designed to change the pressurized enclosure internals from a Zone 1 area into a safe area. This system is designed in accordance with European and International standards and is certified by IECEx and ATEX.  This system uses a compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in an enclosure in order to keep those gases from returning. This unit has 2 pole, 6A AC1 at 250V or 5Amps DC1, at 30V for power switching in addtion to alarm switching.  The SmartPurge II units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system. The unit comes complete with control unit, spark arrestor, and relief valve. <a href="http://www.expoworldwide.com/wp-content/uploads/SmartPurge2-Datasheet.pdf">Click here </a>for more details.</p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/SmartPurge2-Datasheet.pdf" target="_blank">SmartPurge II Datasheet</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/SmartPurge2-IECEx-FME-11_0006.pdf" target="_blank">IECEx Certificate<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/SmartPurge2-FM11ATEX0060.pdf" target="_blank">ATEX Certificate</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML484-v3-SmartPurge-Manual.pdf">SmartPurge II Manual</a></p>
<p>&nbsp;</p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/smartpurge-ii/">SmartPurge II</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/smartpurge-ii/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XCF/SS/PO</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspo/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspo/#comments</comments>
		<pubDate>Sun, 10 Jul 2011 16:09:35 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>
		<category><![CDATA[featured]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=147</guid>
		<description><![CDATA[<p>1XCF/SS/PO-For the protection of general purpose equipment being installed in a Class I Division 1 or Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspo/">1XCF/SS/PO</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1XCF/SS/PO system from Expo is designed to change the pressurized enclosure internals from a Zone 1 or Class I Division 1 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in an enclosure in order to keep those gases from returning. This unit, when used in conjunction with a MIU (MiniPurge Interface Unit) for power and alarm switching, is all that is required to install your equipment into a hazardous area. X-Purge units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPXCF-11-08.pdf" target="_blank">XCF Datasheet</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspo/">1XCF/SS/PO</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspo/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XCF/SS/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfssis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfssis/#comments</comments>
		<pubDate>Tue, 28 Jun 2011 13:19:00 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>
		<category><![CDATA[featured]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1</guid>
		<description><![CDATA[<p>1XCF/SS/IS- For the protection of general purpose equipment being installed in a Class I Division 1 or Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfssis/">1XCF/SS/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller</p>
<p>The 1XCF/SS/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 1 or Class I Division 1 area into a safe area.  This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus.  This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in the enclosure in order to keep those gases from returning.  X-Purge units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system.  The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering.  Click here for more details</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a><br />
<strong><br />
Certification</strong>:<br />
cULus <a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">e190061<br />
</a>FM <a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">fm1x8a4.ae<br />
</a>IECEx <a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07.0027X<br />
</a>ATEX <a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">SIRA 01ATEX1295x</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?SIRA-01ATEX1295x2.pdf" target="_blank"><br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a><br />
<strong><br />
Data Sheet</strong>:<br />
MiniPurge 1XCF <a href="http://www.expoworldwide.com/wp-content/uploads/MPXCF-11-08.pdf" target="_blank">MPXCF-11-08</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?MPXLC%2011-08.pdf" target="_blank"><br />
</a><br />
<strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfssis/">1XCF/SS/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfssis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XCF/SS/PA</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspa/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspa/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:13:37 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>
		<category><![CDATA[featured]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=194</guid>
		<description><![CDATA[<p>1XCF/SS/PA- For the protection of general purpose equipment being installed in a Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspa/">1XCF/SS/PA</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1XCF/SS/PA system from Expo is designed to change the pressurized enclosure internals from a Zone 1 area into a safe area. This system is designed in accordance with European, International, and Brazilian standards and is certified by IECEx, ATEX, and INMETRO. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in an enclosure in order to keep those gases from returning. The PA unit comes with power switching capabilities built in. X-Purge units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook Up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MIU_e-TÜV-12.1463.pdf" target="_blank">INMETRO MIU e Certificate TÜV 12.1463</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPXCF-11-08.pdf" target="_blank">XCF Datasheet</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspa/">1XCF/SS/PA</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xcfsspa/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XLC/SS/PO</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspo/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspo/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:14:47 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=200</guid>
		<description><![CDATA[<p>1XLC/SS/PO- For the protection of general purpose equipment being installed in a Class I Division 1 or Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspo/">1XLC/SS/PO</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1XLC/SS/PO system from Expo is designed to change the pressurized enclosure internals from a Zone 1 or Class I Division 1 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of hazardous gases more rapidly. After the high purge flow rate is complete, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1XLC system is cost-efficient to run. This unit, when used in conjunction with a MIU (MiniPurge Interface Unit) for power and alarm switching, is all that is required to install your equipment into a hazardous area. X-Purge units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook Up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPXLC-11-08.pdf" target="_blank">XLC Datasheet</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspo/">1XLC/SS/PO</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspo/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XLC/SS/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcssis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcssis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:14:26 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=198</guid>
		<description><![CDATA[<p>1XLC/SS/IS- For the protection of general purpose equipment being installed in a Class I Division 1 or Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcssis/">1XLC/SS/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1XLC/SS/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 1 or Class I Division 1 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of hazardous gases more rapidly. After the high purge flow rate is complete, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1XLC system is cost-efficient to run. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook Up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV-12.1462</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPXLC-11-08.pdf" target="_blank">XLC Datasheet</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcssis/">1XLC/SS/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcssis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1XLC/SS/PA</title>
		<link>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspa/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspa/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:15:06 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[X-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=202</guid>
		<description><![CDATA[<p>1XLC/SS/PA- For the protection of general purpose equipment being installed in a Zone 1 areas</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspa/">1XLC/SS/PA</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1XLC/SS/PA system from Expo is designed to change the pressurized enclosure internals from a Zone 1 area into a safe area. This system is designed in accordance with European, International, and Brazilian standards and is certified by IECEx, ATEX, and INMETRO. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of hazardous gases more rapidly. After the high purge flow rate is complete, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1XLC system is cost-efficient to run. The PA unit comes with power switching capabilities built in. X-Purge units are fully automatic; they have timers and control signals that will apply and disengage power based upon the conditions reported by the purge system. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-7TD0-001-Cutouts-and-drillings-for-fitting-MiniPurges.dwg" target="_blank">XSD-7TD0-001 Cutouts and drillings for fitting MiniPurge</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-002-MiniPurge-Dimensions-and-Circuits-Sales-Brochure.dwg" target="_blank">XBR-7TD0-002 MiniPurge Dimensions and Hook Up</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-003-MiniPurge-Installation-Sales-Brochure.dwg" target="_blank">XBR-7TD0-003 MiniPurge Installation</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-004-Cutouts-and-drillings-for-fitting-MiniPurges-Sales-Brochure.dwg" target="_blank">XBR-7TD0-004 Alternative Mounting Options</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MIU_e-TÜV-12.1463.pdf" target="_blank">INMETRO MIU e Certificate TÜV 12.1463</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPXLC-11-08.pdf" target="_blank">XLC Datasheet</a></p>
<p><strong>Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?ML442-V5C.pdf">X Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspa/">1XLC/SS/PA</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/x-purge/1xlcsspa/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1YCF/BP/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfbpis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfbpis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:17:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Y-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=206</guid>
		<description><![CDATA[<p>1YCF/BP/IS- For protecting Class I Division 2 or Zone 2 electrical equipment being installed in a Class I Division 1 or Zone 1 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfbpis/">1YCF/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1YCF/BP/IS system from Expo is designed to allow the user to install Zone 2 or Class I Division 2 certified equipment into Zone 1 or Class I Division 1 areas. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX,INMETRO, cULus, and cFMus. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in the enclosure in order to keep those gases from returning. Y-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-001.dwg" target="_blank">XSD-RTD0-001- Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-012-ZorY-CF-and-DP-bp-quick-installation-guide.dwg" target="_blank">XBR-8TD0-012 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?SAU25-GA.dwg" target="_blank">SAU-GA Spark Arrestor<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?MZ-1CF-17-GA-Size-1-ZorY-CF-bp-IS.dwg" target="_blank">MZ-1CF-17-GA General Arrangment Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZCF-11-08.pdf" target="_blank">YCF Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML432-Issue9.pdf" target="_blank">Y Purge Manaul</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfbpis/">1YCF/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfbpis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1YCF/PM/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:17:51 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Y-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=208</guid>
		<description><![CDATA[<p>1YCF/PM/IS- For protecting Class I Division 2 or Zone 2 electrical equipment being installed in a Class I Division 1 or Zone 1 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis/">1YCF/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1YCF/PM/IS system from Expo is designed to allow the user to install Zone 2 or Class I Division 2 certified equipment into Zone 1 or Class I Division 1 areas. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in the enclosure in order to keep those gases from returning. Y-Purge units are manual units; the user is required to time out the purge cycle and control the power in the enclosure. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-001.dwg" target="_blank">XSD-RTD0-001 Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-010-ZorY-CF-and-DP-pm-quick-installation-guide.dwg" target="_blank">XBR-8TD0-010 Quick Installation Guide</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-012-ZorY-CF-and-DP-bp-quick-installation-guide.dwg" target="_blank"><br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?SAU25-GA.dwg" target="_blank">SAU25-GA Spark Arrestor<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?MZ-1CF-23-GA.dwg" target="_blank">MZ-1CF-23-GA General Arrangement Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZCF-11-08.pdf" target="_blank">YCF Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML432-Issue9.pdf" target="_blank">Y Purge Manaul</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis/">1YCF/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1YCF/PM/IS-blank</title>
		<link>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis-z/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis-z/#comments</comments>
		<pubDate>Tue, 20 Sep 2011 13:58:47 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Y-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=1094</guid>
		<description><![CDATA[<p>[blank]</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis-z/">1YCF/PM/IS-blank</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>[blank]</p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis-z/">1YCF/PM/IS-blank</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/y-purge/1ycfpmis-z/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1YLC/BP/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcbpis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcbpis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:18:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Y-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=210</guid>
		<description><![CDATA[<p>1YLC/BP/IS- For protecting Class I Division 2 or Zone 2 electrical equipment being installed in a Class I Division 1 or Zone 1 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcbpis/">1YLC/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1YLC/BP/IS system from Expo is designed to allow the user to install Zone 2 or Class I Division 2 certified equipment into Zone 1 or Class I Division 1 areas. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of the hazardous gases more rapidly. After the high purge flow rate completes, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1YLC system is cost-efficient to run. Y-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-004-Relief-Valves-ZorY-LC-systems.dwg" target="_blank">XSD-RTD0-004 Relief Valves<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-011-LC-bp-Quick-installation-guide.dwg" target="_blank">XBR-8TD0-011 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-030-Sizes1-2-3-ZorY-LC-bp-IS-PO.dwg" target="_blank">XBR-7TD0-030 General Arrangment Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZLC-11-08.pdf" target="_blank">YLC Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML447-v12-.pdf" target="_blank">Y Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcbpis/">1YLC/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcbpis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1YLC/PM/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcpmis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcpmis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:18:25 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Y-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=212</guid>
		<description><![CDATA[<p>1YLC/PM/IS- For protecting Class I Division 2 or Zone 2 electrical equipment being installed in a Class I Division 1 or Zone 1 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcpmis/">1YLC/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1YLC/PM/IS system from Expo is designed to allow the user to install Zone 2 or Class I Division 2 certified equipment into Zone 1 or Class I Division 1 areas. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of the hazardous gases more rapidly. After the high purge flow rate completes, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1YLC system is cost-efficient to run. Y-Purge units are manual units in that the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-004-Relief-Valves-ZorY-LC-systems1.dwg" target="_blank">XSD-RTD0-004 Relief Valves<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-009-LC-PM-quick-installation-guide.dwg" target="_blank">XBR-8TD0-009 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-029-Sizes1-2-3-ZorY-LC-PM-IS-PO.dwg" target="_blank">XBR-7TD0-029 General Arrangement Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZLC-11-08.pdf" target="_blank">YLC Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML447-v12-.pdf" target="_blank">Y Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcpmis/">1YLC/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/y-purge/1ylcpmis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1ZCF/BP/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfbpis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfbpis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:18:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Z-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=214</guid>
		<description><![CDATA[<p>1ZCF/BP/IS- For the protection of general purpose electrical equipment being installed in a Class I Division 2 or Zone 2 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfbpis/">1ZCF/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1ZCF/BP/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 2 or Class I Division 2 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX,INMETRO, cULus, and cFMus. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in the enclosure in order to keep the gases from returning. Z-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-001.dwg" target="_blank">XSD-RTD0-001 Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-012-ZorY-CF-and-DP-bp-quick-installation-guide.dwg" target="_blank">XBR-8TD0-012 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?SAU25-GA.dwg" target="_blank">SAU25-GA Spark Arrestor<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?MZ-1CF-17-GA-Size-1-ZorY-CF-bp-IS.dwg" target="_blank">MZ-1CF-17-GA General Arrangment Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZCF-11-08.pdf" target="_blank">ZCF Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML432-Issue9.pdf" target="_blank">Z Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfbpis/">1ZCF/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfbpis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1ZCF/PM/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfpmis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfpmis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:19:01 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Z-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=216</guid>
		<description><![CDATA[<p>1ZCF/PM/IS- For the protection of general purpose electrical equipment being installed in a Class I Division 2 or Zone 2 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfpmis/">1ZCF/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 17 cubic feet and smaller<br />
The 1ZCF/PM/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 2 or Class I Division 2 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX,INMETRO, cULus, and cFMus. This system uses a continuous flow of compressed air or inert gas to purge out the hazardous gases and maintain the positive pressure that is needed in the enclosure in order to keep the gases from returning. Z-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit, spark arrestor, and relief valve all bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-001.dwg" target="_blank">XSD-RTD0-001 Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-010-ZorY-CF-and-DP-pm-quick-installation-guide.dwg" target="_blank">XBR-8TD0-010 Quick Installation Guide</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-012-ZorY-CF-and-DP-bp-quick-installation-guide.dwg" target="_blank"><br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?SAU25-GA.dwg" target="_blank">SAU25-GA Spark Arrestor<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?MZ-1CF-23-GA.dwg" target="_blank">MZ-1CF-23-GA General Arrangement Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZCF-11-08.pdf" target="_blank">ZCF Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML432-Issue9.pdf" target="_blank">Z Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfpmis/">1ZCF/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/z-purge/1zcfpmis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1ZLC/BP/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcbpis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcbpis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:19:24 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Z-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=218</guid>
		<description><![CDATA[<p>1ZLC/BP/IS- For the protection of general purpose electrical equipment being installed in a Class I Division 2 or Zone 2 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcbpis/">1ZLC/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1ZLC/BP/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 2 or Class I Division 2 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of the hazardous gases more rapidly. After the high purge flow rate is complete, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1ZLC system is cost-efficient to run. Z-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-004-Relief-Valves-ZorY-LC-systems.dwg" target="_blank">XSD-RTD0-004 Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-011-LC-bp-Quick-installation-guide.dwg" target="_blank">XBR-8TD0-011 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-030-Sizes1-2-3-ZorY-LC-bp-IS-PO.dwg" target="_blank">XBR-7TD0-030 General Arrangement Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZLC-11-08.pdf" target="_blank">ZLC Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML447-v12-.pdf" target="_blank">Z Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcbpis/">1ZLC/BP/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcbpis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1ZLC/PM/IS</title>
		<link>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcpmis/</link>
		<comments>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcpmis/#comments</comments>
		<pubDate>Mon, 11 Jul 2011 15:19:40 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Z-Purge]]></category>

		<guid isPermaLink="false">http://www.expoworldwide.com/?p=220</guid>
		<description><![CDATA[<p>1ZLC/PM/IS- For the protection of general purpose electrical equipment being installed in a Class I Division 2 or Zone 2 area</p><p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcpmis/">1ZLC/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></description>
				<content:encoded><![CDATA[<p>For enclosures 60 cubic feet and smaller<br />
The 1ZLC/PM/IS system from Expo is designed to change the pressurized enclosure internals from a Zone 2 or Class I Division 2 area into a safe area. This system is designed in accordance with European, International, North American, and Brazilian standards and is certified by IECEx, ATEX, INMETRO, cULus, and cFMus. This system uses a leakage compensation method of protecting the enclosure. This method provides the user with a high purge flow rate to rid the enclosure of the hazardous gases more rapidly. After the high purge flow rate completes, the system switches to leakage compensation mode where it provides the needed flow to maintain a positive pressure in the enclosure. The 1ZLC system is cost-efficient to run. Z-Purge units are manual units; the user is required to time out the purge cycle and control the power going into the enclosure. The unit comes complete with control unit and relief valve bundled under one part code for easy ordering. Click here for more details.</p>
<p><strong>Drawings</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XSD-RTD0-004-Relief-Valves-ZorY-LC-systems1.dwg" target="_blank">XSD-RTD0-004 Relief Valve<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-8TD0-009-LC-PM-quick-installation-guide.dwg" target="_blank">XBR-8TD0-009 Quick Installation Guide<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/go.php?XBR-7TD0-029-Sizes1-2-3-ZorY-LC-PM-IS-PO.dwg" target="_blank">XBR-7TD0-029 General Arrangement Drawing</a></p>
<p><strong>Certification</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/e190061.pdf" target="_blank">cULus e190061<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-FM-cert-1X8A4_AE-03Mar11.pdf" target="_blank">FM1x8a4.ae<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/IECEx-SIR-07.0027X_Iss6.pdf" target="_blank">IECEx SIR 07-0027X<br />
</a><a href="http://www.expoworldwide.com/wp-content/uploads/Sira-01ATEX1295X.pdf" target="_blank">ATEX SIRA 01ATEX1295x</a><br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MiniPurge-TÜV-12.1462-X.pdf" target="_blank">INMETRO Purge Certificate TÜV 12.1462X</a></p>
<p><strong>Data Sheet</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/MPZLC-11-08.pdf" target="_blank">ZLC Datasheet</a><br />
<strong><br />
Manuals</strong>:<br />
<a href="http://www.expoworldwide.com/wp-content/uploads/ML447-v12-.pdf" target="_blank">Z Purge Manual</a></p>
<p>The post <a href="http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcpmis/">1ZLC/PM/IS</a> appeared first on <a href="http://www.expoworldwide.com">Expo Technologies</a>.</p>]]></content:encoded>
			<wfw:commentRss>http://www.expoworldwide.com/purge-pressurization/z-purge/1zlcpmis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
