Skip to main content
Simplifying Complexity. Delivering Safety.
Expo
Simplifying Complexity.
Delivering Safety.

SmartPurge Z

Fully Automatic Type Z Purge & Pressurization System for Zone 2,Class I Div 2 Gas Applications

Features

  • Purges enclosures up to 6.1m3
  • Automatic leakage compensation
  • LED status indication
  • All-in-one unit for simple installation
  • Super-fast commissioning
  • ATEX, IECEx, UL, UKEX, PESO, CCC, INMETRO certified

Speak with our experts

Contact Us

Got a question?

For more information contact your local partner to speak to one of our purge and pressurization experts or contact us.

  • Description
  • Specifications
  • Downloads
  • Certificates
  • Manuals
  • Video
  • 3D Models

Description

Simplifying Purge and Pressurization

The SmartPurge Z is a fully certified purge and pressurization system for Zone 2 hazardous area applications. When fitted to a suitable enclosure, the system enables standard uncertified electrical equipment to be operated safely in a hazardous location.

Simple to install and configure, and able to purge a wide range of enclosure sizes, SmartPurge Z is ideally suited for use with OEM systems, gas analyzers, DCS systems and other electrical enclosures.

The system comprises the Control Unit (CU), Air Supply Unit (ASU),  Relief Valve (RLV), and Automatic Leakage Compensation Valve (ALCV) within a single compact unit, avoiding the need for interconnection of components. 

  • The CU contains the control logic to monitor flow, pressure, and purge timing, and provides system outputs.
  • The ASU delivers air to the enclosure during the purge phase.
  • The RLV provides a metered vent for the purge air flow and gives overpressure protection for the enclosure, using our patented, magnetically-set exhaust valve (with an integrated spark-arrestor)
  • The ALCV supplies air in response to changes in the enclosure pressure to maintain a stable pressure, avoiding the need to manually adjust the flow rate for leakage compensation during commissioning, and over the life of the enclosure.

Specifications

Maximum enclosure size
6.1m3 (ATEX/IECEx 5 volume changes) / (NFPA 4 volume changes)
Inlet connection / pressure range
1/4" NPT (F) / 4.0-5.0 bar (must be regulated at inlet)
Operating temperature range
-20 to 58°C (-4 to +136°F)
Purging mode
Automatic leakage compensation up to 90 NLPM (3.2 SCFM)
Hazardous environment
Zone 2, Class I Div 2
Approvals
IECEx; ATEX; UL; UKEX; PESO; INMETRO; CCC
Housing material
Glass Reinforced Polycarbonate (GRP)
Ingress protection
Maintains IP66 or UL50E NEMA 4X
Weight
3kg (6.6lb)
Power supply
DC: 18-30V; AC: 90-254V
Status indication
Green flashing: purge in progress; Green solid: enclosure pressurized; Red: alarm
Outputs
Low pressure alarm, N.O. volt-free contacts
Purge timing
Adjustable 1-99 minutes

Video