Keeping cool

Working with a leading manufacturer of industrial heating systems to develop a large, multi-compartment Ex p panel.

 
Project brief
  • The client required a very large purged and pressurised enclosure to contain the control systems and thyristors for a large heating application in a hazardous area.

Challenges:
  • Design and construct a large multi-compartment Ex p enclosure suitable for a wide operating temperature range of  -20 to +70oC
  • Bespoke door-mounting arrangement required for client’s certified buttons and lamps. 
  • Thyristors have a high heat output, so a special cooling solution was required.
  • IECEx certification was required for zone 2
Outcome:
  • A heavy-duty, 4 door enclosure, with a custom internally mounted X-purge system for elevated external temperature operation
  • Certified internal anti-frost heating for low temperature system starts
  • Special non-gland cable transit system
  • An IECEx approved air conditioning unit installed to remove the high internal heat load
  • Certification: IECEx
Expo products & services
  • Fully custom pressurised enclosure design and build
  • Custom purge systems
  • Purgeable hazardous area air conditioning unit
  • Expo Consultancy & Certification service